RESISTANCE MEASUREMENTS
WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all
capacitors before taking any resistance measurements. Remove the batteries and unplug the line
cords.
1. Set the function switch to the position.
2. Insert the black test lead banana plug into the negative COM
jack.
Insert the red test lead banana plug into the positive jack.
3. Touch the test probe tips across the circuit or component
under test. It is best to disconnect one side of the circuit under
test so the rest of the circuit will not interfere with the
resistance reading.
4. Read the resistance in the display.
CONTINUITY CHECK
WARNING: To avoid electric shock, never measure continuity on circuits or wires that have
voltage on them.
1. Set the function switch to the position.
2. Insert the black lead banana plug into the negative COM
jack.
3. Insert the red test lead banana plug into the positive
jack.
4. Use the MODE button to view the icon on the display.
5. Touch the test probe tips to the circuit or wire you wish
to check.
6. If the resistance is less than approximately 100, the
audible signal will sound. If the circuit is ‘open’ (bad), the
display will indicate “OL”.